Chemical Container Creherit High Airflow Hydrophobic PE Vent Liner
PHYSICAL PROPERTIES |
REFERED TEST STANDARD |
UNIT |
TYPICAL DATA |
Membrane Color |
/ |
/ |
Grey |
Membrane Construction |
/ |
/ |
ePTFE |
Membrane Surface Property |
/ |
/ |
Hydrophobic |
Thickness |
ISO 534 |
mm |
0.01 |
Air Permeability |
ASTM D737 |
ml/min/cm2@7KPa |
>8000 |
Water Entry Pressure |
ASTM D751 |
KPa for 30 sec |
>40 KPa |
Transmission Loss |
Internal Control |
dB |
< 1 dB |
IP Rating (Test I.D.= 2.0mm) |
IEC 60529 |
/ |
IP67/IP68 |
ISO Rating (Test I.D.= 2.0mm) |
ISO 22810 |
/ |
NA |
Operation Temperature |
IEC 60068-2-14 |
℃ |
-40℃ ~ 260℃ |
ROHS |
IEC 62321 |
/ |
Meet ROHS Requirements |
PFOA & PFOS |
US EPA 3550C & US EPA 8321B |
/ |
PFOA & PFOS Free |
Protective Self-Adhesive Ventilation Filter Patch Sticker ePTFE Membrane:
Outdoor cabinets are continuously exposed to harsh environments such as heavy rain, dust, sand, and high winds. Under changing environmental conditions, pressure builds up within a sealed cabinet, putting stress on the seals. Over time, pressure can cause seals to fail, allowing water, corrosive liquids, salts, and particles to enter the cabinet and damage the electronics inside. DCCK
Protective vents are the leading solution for protecting sensitive electronic equipment. DCCK guard vents equalize pressure and reduce condensation by allowing air to move freely in and out of sealed cabinets. At the same time, they provide a long-lasting barrier to protect electronic devices from contamination. The result is improved reliability, safety and product life of sealed electronic devices.
Transmission Loss of AYN-100G10 acoustics membrane < 1dB @ 1KHz, and < 3.5 dB in the whole frequency range.

Shelf life is 5 years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80°F (27°C) and 60% RH.
All data above are typical data for the membrane raw material, for reference only, and should not be used as special data for outgoing quality control.
All technical information and advice given here is based on Mianjun’s previous experiences and test results. Mianjun gives this information to the best of its knowledge, but assumes no legal responsibility. Customers are asked to check the suitability and usability in the specific application, since the performance of the product can only be judged when all necessary operating data are available.