Leave Your Message

Portable Electronics Waterproof Breathable Acoustic Vents Membrane for Speaker

  • PRODUCT NAME Acoustics Vent Membrane
  • PRODUCT MODEL DCCK-M80T02
  • PRODUCT DESCRIPTION e-PTFE Hydrophobic Acoustics transmission membrane
  • APPLICATION FEILD Acoustics & Electronics
  • APPLICATION PRODUCTS Smart Phone, Earphone, Tablet PC, Microphone

PHYSICAL PROPERTIES

REFERED TEST STANDARD

UNIT

TYPICAL DATA

Membrane Color

/

/

Black

Membrane Construction

/

/

Mesh/ePTFE

Membrane Surface Property

/

/

Hydrophobic

Thickness

ISO 534

mm

0.07

Air Permeability

ASTM D737

ml/min/cm2@7KPa

>18000

Water Entry Pressure

ASTM D751

KPa for 30 sec

NA

Transmission Loss (@1kHz, I.D.= 2.0mm)

Internal Control

dB

< 0.3 dB

IP Rating (Test I.D.= 2.0mm)

IEC 60529

/

IP65/IP66

ISO Rating (Test I.D.= 2.0mm)

ISO 22810

/

NA

Operation Temperature

IEC 60068-2-14

-40℃ ~ 150℃

ROHS

IEC 62321

/

Meet ROHS Requirements

PFOA & PFOS

US EPA 3550C & US EPA 8321B

/

PFOA & PFOS Free

Transmission Loss of AYN-M80T02 acoustics membrane < 0.3 dB @ 1KHz, and < 3 dB in the whole frequency range.

Transmission Loss Curve

(1) Acoustic Response and IP Grade test part dimension: I.D. 2.0 mm / O.D. 6.0 mm.  
(2) The results are tested using a typical digital output MEMS microphone system and self-designed test device in AYNUO laboratory  with representative sample size.  The design of the device  will affect final performance. 

This series of membranes can be used in waterproof and acoustics  membrane for portable and wearable electronic devices, such as Smart Phone, Earphone, Smart Watch, and Bluetooth Speaker, Alertor etc.
The membrane could provide the device with immersed waterproof protection and minimal sound transmission loss, keeping the device with the excellent acoustics transmission performance.

Shelf life is 5 years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80°F (27°C) and 60% RH.

All data above are typical data for the membrane raw material, for reference only, and should not be used as special   data for outgoing quality control.

All technical information and advice given here is based on Mianjun’s previous experiences and test results. Mianjun gives this information to the best of its knowledge, but assumes no legal responsibility. Customers are asked to check the   suitability and usability in the specific application, since the performance of the product can only be judged when all  necessary operating data are available.